The EPA 608 Core study guide covers the legal foundation that every section shares, and EPA 608 certification as a whole is what that foundation belongs to. Type 1 adds the recovery thresholds, equipment rules, and access procedures that apply only to small appliances, and this page covers everything the 25 question section tests.

What EPA 608 Type 1 certification covers

EPA 608 Type 1 certification authorizes technicians to service small appliances, which are hermetically sealed systems manufactured with 5 pounds or less of refrigerant, under Section 608 of the Clean Air Act. "Hermetically sealed at the factory" is the critical qualifier. The seal is applied during manufacturing, not by the technician in the field. Type 1 equipment is designed so that normal service does not require opening the refrigerant circuit. When it does become necessary, specific procedures apply.

Type 1 refrigerants are typically R-12 (older equipment, now phased out), R-134a, R-600a (isobutane, increasingly common in newer appliances), and R-290 (propane, in some commercial units). The specific refrigerant in the equipment determines which recovery procedure applies, but the 5 pound rule determines whether Type 1 or Type 2 certification is required.

The 5 pound rule: identifying Type 1 equipment

The 5 pound rule defines the boundary between Type 1 and Type 2: any appliance manufactured with 5 pounds or less of refrigerant, hermetically sealed at the factory, is a Type 1 small appliance.

Appliance Typical refrigerant Typically ≤5 lbs? Certification required
Household refrigerator R-134a or R-600a YES Type 1
Household freezer R-134a or R-600a YES Type 1
Window air conditioner R-22, R-410A, or R-32 YES (most units) Type 1
Dehumidifier R-134a YES Type 1
Vending machine R-134a or R-12 YES Type 1
Drinking water cooler R-134a YES Type 1
Residential split system R-410A or R-32 NO (typically 6 to 15 lbs) Type 2
Walk in cooler R-404A or R-448A NO Type 2

The "manufactured with" standard is important. The question is not how much refrigerant the unit currently contains. It is how much the unit was manufactured to contain. A refrigerator that has been overcharged in the field still qualifies as a Type 1 appliance because it was manufactured with 5 pounds or less.

Type 1 recovery standards: 80% vs 90%

Type 1 recovery standards have two thresholds, both based on the operational status of the compressor at the time of recovery.

The rule in one line: compressor operating = 90% recovery, compressor not operating = 80% recovery, or evacuate the appliance to 4 inches of mercury vacuum. The 4 inch vacuum is an alternative standard that satisfies the requirement either way, and it appears on the exam as often as the percentages do (40 CFR 82.158).

Recovery equipment built Compressor operating Compressor not operating Alternative standard
After November 15, 1993 (must be lab certified) 90% 80% 4 in Hg vacuum
Before November 15, 1993 80% 80% 4 in Hg vacuum

Equipment manufactured after November 15, 1993 must also be certified by an EPA approved testing organization. The thresholds apply whether you recover with system dependent or self contained equipment. The de minimis exemption covers only what escapes despite a good faith recovery attempt, so it never excuses stopping short of the 80% standard.

System dependent vs self contained recovery equipment

System dependent recovery equipment uses the appliance's own compressor to remove the refrigerant; self contained recovery equipment has its own compressor and works independently of the appliance. The Type 1 exam pairs that distinction with the 80%/90% threshold decision.

System dependent equipment is inexpensive and needs no separate recovery machine, but it requires a functioning compressor and is slower than self contained equipment for larger charges. Application: most household refrigerator and freezer service where the compressor is functional.

Self contained equipment works when the appliance compressor is not functional, is faster for larger charges, and reaches higher recovery rates, at the cost of owning the machine and transporting it to the service site. Application: appliances whose compressor is not operating, where the 80% threshold applies.

Two limits the exam tests directly: system dependent (passive) equipment may only be used on appliances containing 15 pounds or less of refrigerant, and when the compressor does not run, passive recovery requires accessing both the high side and the low side of the system. Heating and gently tapping the compressor helps release refrigerant trapped in the oil. Exam scenarios chain compressor status to the recovery threshold, then to the equipment type.

Process stubs and accessing sealed systems

A process stub is a short copper tube attached to the refrigerant circuit during manufacturing and left pinched off, and it is the access point for a hermetically sealed small appliance. To access the sealed system, a technician attaches a piercing valve or saddle valve to the process stub, then taps into the circuit.

Process stubs are the only approved access point for Type 1 equipment; the sealed circuit has no standard service ports. Leak test every piercing valve after installation, and never leave a solderless piercing valve on the system permanently. They leak over time, which is why the exam flags them as temporary access only.

After completing work, the process stub access must be resealed. Leaving the circuit open after service is a Section 608 violation.

Recover before disposal: Refrigerant must be recovered from a small appliance before it is scrapped or landfilled. The final person in the disposal chain (a scrap yard or landfill) is responsible for verifying recovery, either by recovering the refrigerant themselves or by obtaining a signed statement that it was already recovered. Tossing a refrigerator with its charge intact is a Section 608 violation for whoever disposes of it.

Disposable cylinder prohibition: Recovered refrigerant from any Type 1 appliance must be stored in approved recovery cylinders that are DOT approved, color coded with a gray body and yellow collar (for mixed refrigerants) or refrigerant specific markings. Transferring recovered refrigerant into disposable (throwaway) cylinders is prohibited under 40 CFR Part 82. Disposables are not rated for recovery pressures.

EPA 608 Type 1 open book: 21 of 25, and where it stops

The EPA 608 open book route is a mail-in, unproctored exam that some certifying organizations offer for the Type 1 section and the Core section, and it passes at 21 of 25 (84%) instead of the proctored 18 of 25 (72%). A Core section passed open book does not count toward Universal: EPA requires a proctored Core for Universal certification, so the EPA 608 Universal study guide sequence starts with a proctored Core. Type 2, Type 3, and Universal are proctored only.

Route Passing score Core counts toward Universal?
Proctored (testing site or online proctor) 18 of 25 (72%) YES
Open book, mail-in (Type 1 and Core, by organization) 21 of 25 (84%) NO

The proctored passing score is 18 of 25 (72%) at every organization; the EPA 608 test page covers scoring and retakes for ESCO, Mainstream, and HVAC Excellence.

AIM Act impact on Type 1 appliances

The American Innovation and Manufacturing (AIM) Act is phasing down HFCs based on global warming potential (GWP). For Type 1 technicians, this means household refrigerators and small appliances are increasingly transitioning from R-134a to low GWP refrigerants like R-600a (isobutane) and R-290 (propane). These A3 (flammable) refrigerants require different safety protocols, standard recovery equipment may not be rated for them, and retrofitting an existing CFC or HFC system to a hydrocarbon refrigerant is prohibited. R-600a and R-290 are approved for listed new equipment only.

The EPA 608 Type 2 study guide covers how the AIM Act phase down affects the larger systems in the other sections. The R-22 phase out itself is a Clean Air Act ozone rule, not an AIM Act rule, and the exam tests the two apart.

Type 1 FAQ

Does a refrigerator need Type 1 or Type 2 certification?
A household refrigerator requires EPA 608 Type 1. It is hermetically sealed at the factory and manufactured with 5 pounds or less of refrigerant, meeting the Type 1 small appliance definition.
How many questions are on the Type 1 EPA 608 exam?
The Type 1 section contains 25 questions. Passing requires 18 correct, which is 72%. The Type 1 exam is taken in addition to the Core section, and both must be passed for Type 1 certification.
Can I use a disposable cylinder for Type 1 recovery?
No. Recovered refrigerant must be stored in approved DOT recovery cylinders. Transferring to disposable cylinders is prohibited under Section 608 regardless of refrigerant type or appliance category.
Do I have to recover refrigerant before disposing of a small appliance?
Yes. Refrigerant must be recovered before a small appliance is scrapped. The final person in the disposal chain is responsible, either by recovering the charge or by obtaining a signed statement that recovery was already done.

Practice Type 1 questions

Drill the 5 pound rule, the 80%/90% recovery thresholds, system dependent vs self contained equipment, and process stub procedures against 604 verified questions.

Aligned with ESCO Institute, Mainstream Engineering, and HVAC Excellence exam formats.

Part of the EPA 608 study guides collection

This Type 1 study guide is part of our complete EPA 608 study guide library, covering Core, Type 1, Type 2, Type 3, Universal, and a condensed cheat sheet for last minute review. Type 2 and Universal are linked in the AIM Act and open book sections on this page; the EPA 608 Type 3 study guide covers low pressure chillers.